Strutt

Strutt Help



Standardise RT to 0.5s

Strutt|Building Acoustics|Standardise to 0.5s RT provides the correction needed to standardise a given row of Reverberation Times (RT) to a reference level of 0.5s, using the formula:

Correction `= 10log_10((RT)/0.5)`


Comments or suggestions to