Strutt|Building Acoustics|Absorption from Heavyweight Wall inserts the minimum absorption coefficient (due to dissipation in the acoustic boundary layer) that will occur from a heavy rigid wall. This is the lower bound of the absorption coefficient from a wall, and is calculated as:
`alpha_(min)=1.8*10^-4(f)^0.5`